[v1] test_plans/dpdk_gro_lib_test_plan.rst

Message ID 20200921100241.391356-1-yinan.wang@intel.com (mailing list archive)
State Changes Requested
Headers
Series [v1] test_plans/dpdk_gro_lib_test_plan.rst |

Commit Message

Wang, Yinan Sept. 21, 2020, 10:02 a.m. UTC
  Add 2 queue case for performance check

Signed-off-by: Yinan Wang <yinan.wang@intel.com>
---
 test_plans/dpdk_gro_lib_test_plan.rst | 94 ++++++++++++++++++++++-----
 1 file changed, 76 insertions(+), 18 deletions(-)
  

Comments

Tu, Lijuan Oct. 12, 2020, 7:59 a.m. UTC | #1
> Add 2 queue case for performance check
> 
> Signed-off-by: Yinan Wang <yinan.wang@intel.com>

Applied failed.

CONFLICT (content): Merge conflict in test_plans/dpdk_gro_lib_test_plan.rst
error: Failed to merge in the changes.
Patch failed at 0001 test_plans/dpdk_gro_lib_test_plan.rst
  

Patch

diff --git a/test_plans/dpdk_gro_lib_test_plan.rst b/test_plans/dpdk_gro_lib_test_plan.rst
index ea0244c..59ac0f1 100644
--- a/test_plans/dpdk_gro_lib_test_plan.rst
+++ b/test_plans/dpdk_gro_lib_test_plan.rst
@@ -130,7 +130,7 @@  Test Case1: DPDK GRO lightmode test with tcp/ipv4 traffic
 2. Bind nic1 to igb_uio, launch vhost-user with testpmd and set flush interval to 1::
 
     ./dpdk-devbind.py -b igb_uio xx:xx.x
-    ./testpmd -l 2-4 -n 4 \
+    ./testpmd -l 2-4 -n 4 --socket-mem 1024,1024  --legacy-mem \
     --file-prefix=vhost --vdev 'net_vhost0,iface=vhost-net,queues=1,client=0' -- -i --txd=1024 --rxd=1024
     testpmd>set fwd csum
     testpmd>stop
@@ -151,8 +151,8 @@  Test Case1: DPDK GRO lightmode test with tcp/ipv4 traffic
     taskset -c 13 qemu-system-x86_64 -name us-vhost-vm1 \
        -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on \
        -numa node,memdev=mem \
-       -mem-prealloc -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,macaddr=00:00:00:08:e8:aa,addr=1f -net user,hostfwd=tcp:127.0.0.1:6001-:22 \
-       -smp cores=1,sockets=1 -drive file=/home/osimg/ubuntu16.img  \
+       -mem-prealloc -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6001-:22 \
+       -smp cores=1,sockets=1 -drive file=/home/osimg/ubuntu2004.img  \
        -chardev socket,id=char0,path=./vhost-net \
        -netdev type=vhost-user,id=mynet1,chardev=char0,vhostforce \
        -device virtio-net-pci,mac=52:54:00:00:00:01,netdev=mynet1,mrg_rxbuf=on,csum=on,gso=on,host_tso4=on,guest_tso4=on \
@@ -182,7 +182,7 @@  Test Case2: DPDK GRO heavymode test with tcp/ipv4 traffic
 2. Bind nic1 to igb_uio, launch vhost-user with testpmd and set flush interval to 2::
 
     ./dpdk-devbind.py -b igb_uio xx:xx.x
-    ./testpmd -l 2-4 -n 4 \
+    ./testpmd -l 2-4 -n 4 --socket-mem 1024,1024  --legacy-mem \
     --file-prefix=vhost --vdev 'net_vhost0,iface=vhost-net,queues=1,client=0' -- -i --txd=1024 --rxd=1024
     testpmd>set fwd csum
     testpmd>stop
@@ -203,8 +203,8 @@  Test Case2: DPDK GRO heavymode test with tcp/ipv4 traffic
     taskset -c 13 qemu-system-x86_64 -name us-vhost-vm1 \
        -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on \
        -numa node,memdev=mem \
-       -mem-prealloc -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,macaddr=00:00:00:08:e8:aa,addr=1f -net user,hostfwd=tcp:127.0.0.1:6001-:22 \
-       -smp cores=1,sockets=1 -drive file=/home/osimg/ubuntu16.img  \
+       -mem-prealloc -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6001-:22 \
+       -smp cores=1,sockets=1 -drive file=/home/osimg/ubuntu2004.img  \
        -chardev socket,id=char0,path=./vhost-net \
        -netdev type=vhost-user,id=mynet1,chardev=char0,vhostforce \
        -device virtio-net-pci,mac=52:54:00:00:00:01,netdev=mynet1,mrg_rxbuf=on,csum=on,gso=on,host_tso4=on,guest_tso4=on \
@@ -234,7 +234,7 @@  Test Case3: DPDK GRO heavymode_flush4 test with tcp/ipv4 traffic
 2. Bind nic1 to igb_uio, launch vhost-user with testpmd and set flush interval to 4::
 
     ./dpdk-devbind.py -b igb_uio xx:xx.x
-    ./testpmd -l 2-4 -n 4 \
+    ./testpmd -l 2-4 -n 4 --socket-mem 1024,1024  --legacy-mem \
     --file-prefix=vhost --vdev 'net_vhost0,iface=vhost-net,queues=1,client=0' -- -i --txd=1024 --rxd=1024
     testpmd>set fwd csum
     testpmd>stop
@@ -255,8 +255,8 @@  Test Case3: DPDK GRO heavymode_flush4 test with tcp/ipv4 traffic
     taskset -c 13 qemu-system-x86_64 -name us-vhost-vm1 \
        -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on \
        -numa node,memdev=mem \
-       -mem-prealloc -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,macaddr=00:00:00:08:e8:aa,addr=1f -net user,hostfwd=tcp:127.0.0.1:6001-:22 \
-       -smp cores=1,sockets=1 -drive file=/home/osimg/ubuntu16.img  \
+       -mem-prealloc -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6001-:22 \
+       -smp cores=1,sockets=1 -drive file=/home/osimg/ubuntu2004.img  \
        -chardev socket,id=char0,path=./vhost-net \
        -netdev type=vhost-user,id=mynet1,chardev=char0,vhostforce \
        -device virtio-net-pci,mac=52:54:00:00:00:01,netdev=mynet1,mrg_rxbuf=on,csum=on,gso=on,host_tso4=on,guest_tso4=on \
@@ -301,7 +301,7 @@  Vxlan topology
 2. Bind nic1 to igb_uio, launch vhost-user with testpmd and set flush interval to 4::
 
     ./dpdk-devbind.py -b igb_uio xx:xx.x
-    ./testpmd -l 2-4 -n 4 \
+    ./testpmd -l 2-4 -n 4 --socket-mem 1024,1024  --legacy-mem \
     --file-prefix=vhost --vdev 'net_vhost0,iface=vhost-net,queues=1,client=0' -- -i --txd=1024 --rxd=1024
     testpmd>set fwd csum
     testpmd>stop
@@ -325,8 +325,8 @@  Vxlan topology
     taskset -c 13 qemu-system-x86_64 -name us-vhost-vm1 \
        -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on \
        -numa node,memdev=mem \
-       -mem-prealloc -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,macaddr=00:00:00:08:e8:aa,addr=1f -net user,hostfwd=tcp:127.0.0.1:6001-:22 \
-       -smp cores=1,sockets=1 -drive file=/home/osimg/ubuntu16.img  \
+       -mem-prealloc -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6001-:22 \
+       -smp cores=1,sockets=1 -drive file=/home/osimg/ubuntu2004.img  \
        -chardev socket,id=char0,path=./vhost-net \
        -netdev type=vhost-user,id=mynet1,chardev=char0,vhostforce \
        -device virtio-net-pci,mac=52:54:00:00:00:01,netdev=mynet1,mrg_rxbuf=on,csum=on,gso=on,host_tso4=on,guest_tso4=on \
@@ -346,8 +346,8 @@  Vxlan topology
     Host side :  ip netns exec t2 iperf -c 50.1.1.2 -i 2 -t 60 -f g -m
     VM side:     iperf -s -f g
 
-Test Case5: DPDK GRO test with CBDMA enable using tcp/ipv4 traffic
-==================================================================
+Test Case5: DPDK GRO test with 2 queues using tcp/ipv4 traffic
+==============================================================
 
 Test flow
 =========
@@ -365,8 +365,8 @@  NIC2(In kernel) -> NIC1(DPDK) -> testpmd(csum fwd) -> Vhost -> Virtio-net
 2. Bind cbdma port and nic1 to igb_uio, launch vhost-user with testpmd and set flush interval to 1::
 
     ./dpdk-devbind.py -b igb_uio xx:xx.x
-    ./x86_64-native-linuxapp-gcc/app/testpmd -l 29-30 -n 4 \
-    --file-prefix=vhost --vdev 'net_vhost0,iface=vhost-net,queues=2,dmas=[txq0@80:04.0;txq1@80:04.1],dmathr=1024' -- -i --txd=1024 --rxd=1024 --txq=2 --rxq=2
+    ./x86_64-native-linuxapp-gcc/app/testpmd -l 29-31 -n 4 \
+    --file-prefix=vhost --vdev 'net_vhost0,iface=vhost-net,queues=2' -- -i --txd=1024 --rxd=1024 --txq=2 --rxq=2 --nb-cores=2
     set fwd csum
     stop
     port stop 0
@@ -383,11 +383,11 @@  NIC2(In kernel) -> NIC1(DPDK) -> testpmd(csum fwd) -> Vhost -> Virtio-net
 
 3.  Set up vm with virto device and using kernel virtio-net driver::
 
-    taskset -c 31 /home/qemu-install/qemu-3.0/bin/qemu-system-x86_64 -name us-vhost-vm1 \
+    taskset -c 31 /home/qemu-install/qemu-4.2.1/bin/qemu-system-x86_64 -name us-vhost-vm1 \
        -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on \
        -numa node,memdev=mem \
        -mem-prealloc -monitor unix:/tmp/vm2_monitor.sock,server,nowait -netdev user,id=yinan,hostfwd=tcp:127.0.0.1:6005-:22 -device e1000,netdev=yinan \
-       -smp cores=1,sockets=1 -drive file=/home/osimg/ubuntu1910.img  \
+       -smp cores=1,sockets=1 -drive file=/home/osimg/ubuntu2004.img  \
        -chardev socket,id=char0,path=./vhost-net \
        -netdev type=vhost-user,id=mynet1,chardev=char0,vhostforce,queues=2 \
        -device virtio-net-pci,mac=52:54:00:00:00:01,netdev=mynet1,mrg_rxbuf=on,csum=on,gso=on,host_tso4=on,guest_tso4=on,mq=on,vectors=15 \
@@ -403,3 +403,61 @@  NIC2(In kernel) -> NIC1(DPDK) -> testpmd(csum fwd) -> Vhost -> Virtio-net
 
     Host side :  taskset -c 35 ip netns exec ns1 iperf -c 1.1.1.2 -i 1 -t 60 -m -P 2
     VM side:     iperf -s
+
+Test Case6: DPDK GRO test with CBDMA enable using tcp/ipv4 traffic
+==================================================================
+
+Test flow
+=========
+
+NIC2(In kernel) -> NIC1(DPDK) -> testpmd(csum fwd) -> Vhost -> Virtio-net
+
+1. Connect two nic port directly, put nic2 into another namesapce and turn on the tso of this nic port by below cmds::
+
+    ip netns del ns1
+    ip netns add ns1
+    ip link set enp26s0f0 netns ns1       # [enp216s0f0] is the name of nic2
+    ip netns exec ns1 ifconfig enp26s0f0 1.1.1.8 up
+    ip netns exec ns1 ethtool -K enp26s0f0 tso on
+
+2. Bind cbdma port and nic1 to igb_uio, launch vhost-user with testpmd and set flush interval to 1::
+
+    ./dpdk-devbind.py -b igb_uio xx:xx.x
+    ./x86_64-native-linuxapp-gcc/app/testpmd -l 29-31 -n 4 \
+    --file-prefix=vhost --vdev 'net_vhost0,iface=vhost-net,queues=2,dmas=[txq0@80:04.0;txq1@80:04.1],dmathr=1024' -- -i --txd=1024 --rxd=1024 --txq=2 --rxq=2 --nb-cores=2
+    set fwd csum
+    stop
+    port stop 0
+    port stop 1
+    csum set tcp hw 0
+    csum set ip hw 0
+    csum set tcp hw 1
+    csum set ip hw 1
+    set port 0 gro on
+    set gro flush 1
+    port start 0
+    port start 1
+    start
+
+3.  Set up vm with virto device and using kernel virtio-net driver::
+
+    taskset -c 31 /home/qemu-install/qemu-4.2.1/bin/qemu-system-x86_64 -name us-vhost-vm1 \
+       -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on \
+       -numa node,memdev=mem \
+       -mem-prealloc -monitor unix:/tmp/vm2_monitor.sock,server,nowait -netdev user,id=yinan,hostfwd=tcp:127.0.0.1:6005-:22 -device e1000,netdev=yinan \
+       -smp cores=1,sockets=1 -drive file=/home/osimg/ubuntu2004.img  \
+       -chardev socket,id=char0,path=./vhost-net \
+       -netdev type=vhost-user,id=mynet1,chardev=char0,vhostforce,queues=2 \
+       -device virtio-net-pci,mac=52:54:00:00:00:01,netdev=mynet1,mrg_rxbuf=on,csum=on,gso=on,host_tso4=on,guest_tso4=on,mq=on,vectors=15 \
+       -vnc :10 -daemonize
+
+4. In vm, config the virtio-net device with ip and turn the kernel gro off::
+
+    ifconfig ens4 1.1.1.2 up  # [ens3] is the name of virtio-net
+    ethtool -L ens4 combined 2
+    ethtool -K ens4 gro off
+
+5. Start iperf test, run iperf server at vm side and iperf client at host side, check throughput in log can get better performance than case5::
+
+    Host side :  taskset -c 35 ip netns exec ns1 iperf -c 1.1.1.2 -i 1 -t 60 -m -P 2
+    VM side:     iperf -s