[dpdk-dev,2/3] app/testpmd: enable UDP GSO in the checksum forwarding engine
Checks
Commit Message
This patch enables GSO for UDP/IPv4 packets. Oversized UDP/IPv4
packets transmitted over a GSO-enabled port will undergo segmentation.
Signed-off-by: Jiayu Hu <jiayu.hu@intel.com>
---
app/test-pmd/cmdline.c | 5 +++--
app/test-pmd/csumonly.c | 2 ++
app/test-pmd/testpmd.c | 2 +-
3 files changed, 6 insertions(+), 3 deletions(-)
Comments
Hi Jiayu,
> -----Original Message-----
> From: dev [mailto:dev-bounces@dpdk.org] On Behalf Of Jiayu Hu
> Sent: Tuesday, May 29, 2018 8:41 AM
> To: dev@dpdk.org
> Cc: Ananyev, Konstantin <konstantin.ananyev@intel.com>; Hu, Jiayu
> <jiayu.hu@intel.com>
> Subject: [dpdk-dev] [PATCH 2/3] app/testpmd: enable UDP GSO in the
> checksum forwarding engine
>
> This patch enables GSO for UDP/IPv4 packets. Oversized UDP/IPv4 packets
> transmitted over a GSO-enabled port will undergo segmentation.
>
> Signed-off-by: Jiayu Hu <jiayu.hu@intel.com>
> ---
> app/test-pmd/cmdline.c | 5 +++--
> app/test-pmd/csumonly.c | 2 ++
> app/test-pmd/testpmd.c | 2 +-
> 3 files changed, 6 insertions(+), 3 deletions(-)
>
> diff --git a/app/test-pmd/cmdline.c b/app/test-pmd/cmdline.c index
> 27e2aa8..4239e91 100644
> --- a/app/test-pmd/cmdline.c
> +++ b/app/test-pmd/cmdline.c
> @@ -4792,8 +4792,9 @@ cmd_gso_show_parsed(void *parsed_result,
> if (gso_ports[res->cmd_pid].enable) {
> printf("Max GSO'd packet size: %uB\n"
> "Supported GSO types: TCP/IPv4, "
> - "VxLAN with inner TCP/IPv4 packet, "
> - "GRE with inner TCP/IPv4 packet\n",
> + "UDP/IPv4, VxLAN with inner "
> + "TCP/IPv4 packet, GRE with inner "
> + "TCP/IPv4 packet\n",
This change is giving 3 checkpatch.pl warnings and should be refactored
> gso_max_segment_size);
> } else
> printf("GSO is not enabled on Port %u\n", res-
> >cmd_pid); diff --git a/app/test-pmd/csumonly.c b/app/test-
> pmd/csumonly.c index 0bb88cf..4948292 100644
> --- a/app/test-pmd/csumonly.c
> +++ b/app/test-pmd/csumonly.c
> @@ -411,6 +411,8 @@ process_inner_cksums(void *l3_hdr, const struct
> testpmd_offload_info *info,
> info->ethertype);
> }
> }
> + if (info->gso_enable)
> + ol_flags |= PKT_TX_UDP_SEG;
> } else if (info->l4_proto == IPPROTO_TCP) {
> tcp_hdr = (struct tcp_hdr *)((char *)l3_hdr + info->l3_len);
> tcp_hdr->cksum = 0;
> diff --git a/app/test-pmd/testpmd.c b/app/test-pmd/testpmd.c index
> 35cf266..b5766ff 100644
> --- a/app/test-pmd/testpmd.c
> +++ b/app/test-pmd/testpmd.c
> @@ -777,7 +777,7 @@ init_config(void)
> init_port_config();
>
> gso_types = DEV_TX_OFFLOAD_TCP_TSO |
> DEV_TX_OFFLOAD_VXLAN_TNL_TSO |
> - DEV_TX_OFFLOAD_GRE_TNL_TSO;
> + DEV_TX_OFFLOAD_GRE_TNL_TSO |
> DEV_TX_OFFLOAD_UDP_TSO;
> /*
> * Records which Mbuf pool to use by each logical core, if needed.
> */
> --
> 2.7.4
./devtools/check-git-log.sh -1
Headline too long:
app/testpmd: enable UDP GSO in the checksum forwarding engine
Should the dpdk/doc/guides/testpmd_ap_ug/testpmd_funcs.rst file be updated?
Regards,
Bernard
Hi Bernard,
> -----Original Message-----
> From: Iremonger, Bernard
> Sent: Thursday, June 14, 2018 10:44 PM
> To: Hu, Jiayu <jiayu.hu@intel.com>; dev@dpdk.org
> Cc: Ananyev, Konstantin <konstantin.ananyev@intel.com>; Hu, Jiayu
> <jiayu.hu@intel.com>
> Subject: RE: [dpdk-dev] [PATCH 2/3] app/testpmd: enable UDP GSO in the
> checksum forwarding engine
>
> Hi Jiayu,
>
> > -----Original Message-----
> > From: dev [mailto:dev-bounces@dpdk.org] On Behalf Of Jiayu Hu
> > Sent: Tuesday, May 29, 2018 8:41 AM
> > To: dev@dpdk.org
> > Cc: Ananyev, Konstantin <konstantin.ananyev@intel.com>; Hu, Jiayu
> > <jiayu.hu@intel.com>
> > Subject: [dpdk-dev] [PATCH 2/3] app/testpmd: enable UDP GSO in the
> > checksum forwarding engine
> >
> > This patch enables GSO for UDP/IPv4 packets. Oversized UDP/IPv4
> packets
> > transmitted over a GSO-enabled port will undergo segmentation.
> >
> > Signed-off-by: Jiayu Hu <jiayu.hu@intel.com>
> > ---
> > app/test-pmd/cmdline.c | 5 +++--
> > app/test-pmd/csumonly.c | 2 ++
> > app/test-pmd/testpmd.c | 2 +-
> > 3 files changed, 6 insertions(+), 3 deletions(-)
> >
> > diff --git a/app/test-pmd/cmdline.c b/app/test-pmd/cmdline.c index
> > 27e2aa8..4239e91 100644
> > --- a/app/test-pmd/cmdline.c
> > +++ b/app/test-pmd/cmdline.c
> > @@ -4792,8 +4792,9 @@ cmd_gso_show_parsed(void *parsed_result,
> > if (gso_ports[res->cmd_pid].enable) {
> > printf("Max GSO'd packet size: %uB\n"
> > "Supported GSO types: TCP/IPv4, "
> > - "VxLAN with inner TCP/IPv4 packet,
> "
> > - "GRE with inner TCP/IPv4
> packet\n",
> > + "UDP/IPv4, VxLAN with inner "
> > + "TCP/IPv4 packet, GRE with inner "
> > + "TCP/IPv4 packet\n",
>
> This change is giving 3 checkpatch.pl warnings and should be refactored
The file test-pmd/cmdline.c uses the above coding style to split long strings,
so I think I need to keep this style. But when I use it, there are always some warnings.
>
>
> > gso_max_segment_size);
> > } else
> > printf("GSO is not enabled on Port %u\n", res-
> > >cmd_pid); diff --git a/app/test-pmd/csumonly.c b/app/test-
> > pmd/csumonly.c index 0bb88cf..4948292 100644
> > --- a/app/test-pmd/csumonly.c
> > +++ b/app/test-pmd/csumonly.c
> > @@ -411,6 +411,8 @@ process_inner_cksums(void *l3_hdr, const struct
> > testpmd_offload_info *info,
> > info->ethertype);
> > }
> > }
> > + if (info->gso_enable)
> > + ol_flags |= PKT_TX_UDP_SEG;
> > } else if (info->l4_proto == IPPROTO_TCP) {
> > tcp_hdr = (struct tcp_hdr *)((char *)l3_hdr + info->l3_len);
> > tcp_hdr->cksum = 0;
> > diff --git a/app/test-pmd/testpmd.c b/app/test-pmd/testpmd.c index
> > 35cf266..b5766ff 100644
> > --- a/app/test-pmd/testpmd.c
> > +++ b/app/test-pmd/testpmd.c
> > @@ -777,7 +777,7 @@ init_config(void)
> > init_port_config();
> >
> > gso_types = DEV_TX_OFFLOAD_TCP_TSO |
> > DEV_TX_OFFLOAD_VXLAN_TNL_TSO |
> > - DEV_TX_OFFLOAD_GRE_TNL_TSO;
> > + DEV_TX_OFFLOAD_GRE_TNL_TSO |
> > DEV_TX_OFFLOAD_UDP_TSO;
> > /*
> > * Records which Mbuf pool to use by each logical core, if needed.
> > */
> > --
> > 2.7.4
>
> ./devtools/check-git-log.sh -1
> Headline too long:
> app/testpmd: enable UDP GSO in the checksum forwarding engine
Will change it in the next version.
>
> Should the dpdk/doc/guides/testpmd_ap_ug/testpmd_funcs.rst file be
> updated?
I will add some descriptions about UDP/IPv4 GSO usage guide in it.
Thanks,
Jiayu
>
> Regards,
>
> Bernard
>
@@ -4792,8 +4792,9 @@ cmd_gso_show_parsed(void *parsed_result,
if (gso_ports[res->cmd_pid].enable) {
printf("Max GSO'd packet size: %uB\n"
"Supported GSO types: TCP/IPv4, "
- "VxLAN with inner TCP/IPv4 packet, "
- "GRE with inner TCP/IPv4 packet\n",
+ "UDP/IPv4, VxLAN with inner "
+ "TCP/IPv4 packet, GRE with inner "
+ "TCP/IPv4 packet\n",
gso_max_segment_size);
} else
printf("GSO is not enabled on Port %u\n", res->cmd_pid);
@@ -411,6 +411,8 @@ process_inner_cksums(void *l3_hdr, const struct testpmd_offload_info *info,
info->ethertype);
}
}
+ if (info->gso_enable)
+ ol_flags |= PKT_TX_UDP_SEG;
} else if (info->l4_proto == IPPROTO_TCP) {
tcp_hdr = (struct tcp_hdr *)((char *)l3_hdr + info->l3_len);
tcp_hdr->cksum = 0;
@@ -777,7 +777,7 @@ init_config(void)
init_port_config();
gso_types = DEV_TX_OFFLOAD_TCP_TSO | DEV_TX_OFFLOAD_VXLAN_TNL_TSO |
- DEV_TX_OFFLOAD_GRE_TNL_TSO;
+ DEV_TX_OFFLOAD_GRE_TNL_TSO | DEV_TX_OFFLOAD_UDP_TSO;
/*
* Records which Mbuf pool to use by each logical core, if needed.
*/