[v2,6/7] net/mlx5: check consistency of meter policy and profile
Checks
Commit Message
In the previous implementation, only green color policy was
supported in mlx5 PMD. Since yellow color policy is supported now,
the consistency of meter policy and profile should be checked.
1. If the profile supports yellow but the policy doesn't, an error
should be returned when creating the meter. Or else, there is
no explicit steering action for the packets marked with yellow.
2. If the policy supports yellow but the profile doesn't, it will
be considered as a valid case. Even if no packet will be
handled with the yellow steering action, it is just like that
only the green policy presents.
Usually the green color is supported by default, but when it is
disabled intentionally with setting the CBS to a small value like
zero in the profile, the similar checking on green policy and
profile should also be done.
Signed-off-by: Bing Zhao <bingz@nvidia.com>
---
drivers/net/mlx5/mlx5.h | 2 ++
drivers/net/mlx5/mlx5_flow_meter.c | 16 ++++++++++++++--
2 files changed, 16 insertions(+), 2 deletions(-)
@@ -870,6 +870,8 @@ struct mlx5_flow_meter_profile {
/**< srtcm_rfc2697 struct. */
};
uint32_t ref_cnt; /**< Use count. */
+ uint32_t g_support:1; /**< If G color will be generated. */
+ uint32_t y_support:1; /**< If Y color will be generated. */
};
/* 2 meters in each ASO cache line */
@@ -333,6 +333,10 @@ mlx5_flow_meter_param_fill(struct mlx5_flow_meter_profile *fmp,
ebs_exp = exp;
srtcm->ebs_eir = rte_cpu_to_be_32(ebs_exp << ASO_DSEG_EBS_EXP_OFFSET |
ebs_man << ASO_DSEG_EBS_MAN_OFFSET);
+ if (srtcm->cbs_cir)
+ fmp->g_support = 1;
+ if (srtcm->ebs_eir)
+ fmp->y_support = 1;
return 0;
}
@@ -1136,13 +1140,13 @@ mlx5_flow_meter_create(struct rte_eth_dev *dev, uint32_t meter_id,
if (!priv->config.dv_esw_en)
domain_bitmap &= ~MLX5_MTR_DOMAIN_TRANSFER_BIT;
} else {
- mtr_policy = mlx5_flow_meter_policy_find(dev,
- params->meter_policy_id, &policy_idx);
if (!priv->sh->meter_aso_en)
return -rte_mtr_error_set(error, ENOTSUP,
RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
"Part of the policies cannot be "
"supported without ASO ");
+ mtr_policy = mlx5_flow_meter_policy_find(dev,
+ params->meter_policy_id, &policy_idx);
if (!mtr_policy)
return -rte_mtr_error_set(error, ENOENT,
RTE_MTR_ERROR_TYPE_METER_POLICY_ID,
@@ -1153,6 +1157,14 @@ mlx5_flow_meter_create(struct rte_eth_dev *dev, uint32_t meter_id,
MLX5_MTR_DOMAIN_EGRESS_BIT : 0) |
(mtr_policy->transfer ?
MLX5_MTR_DOMAIN_TRANSFER_BIT : 0);
+ if (fmp->g_support && mtr_policy->skip_g)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_METER_POLICY_ID,
+ NULL, "Meter green policy is empty.");
+ if (fmp->y_support && mtr_policy->skip_y)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_METER_POLICY_ID,
+ NULL, "Meter yellow policy is empty.");
}
/* Allocate the flow meter memory. */
if (priv->sh->meter_aso_en) {