[V2,1/2] test_plans/telemetry:add 22.07 new feature
Commit Message
add 22.07 new feature, support get laser power value in telemetry client.
Signed-off-by: Zhimin Huang <zhiminx.huang@intel.com>
---
test_plans/telemetry_test_plan.rst | 70 +++++++++++++++++++++++++++++-
1 file changed, 69 insertions(+), 1 deletion(-)
Comments
Acked-by: Peng, Yuan <yuan.peng@intel.com>
-----Original Message-----
From: Zhimin Huang <zhiminx.huang@intel.com>
Sent: Friday, August 5, 2022 12:59 AM
To: dts@dpdk.org
Cc: Huang, ZhiminX <zhiminx.huang@intel.com>
Subject: [dts][PATCH V2 1/2] test_plans/telemetry:add 22.07 new feature
add 22.07 new feature, support get laser power value in telemetry client.
Signed-off-by: Zhimin Huang <zhiminx.huang@intel.com>
---
@@ -200,4 +200,72 @@ Test case: Stats of 4 ports for testpmd and telemetry with different type nic
a. Ensure # of ports stats being returned == # of ports
b. Ensure packet counts (eg rx_good_packets) is 0
c. Ensure extended NIC stats are shown (depends on PMD used for testing, refer to ixgbe/i40e tests for PMD xstats)
- d. Ensure extended NIC stats are 0 (eg: rx_q0_packets == 0)
\ No newline at end of file
+ d. Ensure extended NIC stats are 0 (eg: rx_q0_packets == 0)
+
+Test case: read nic Laser Power via dpdk
+========================================
+
+1.Bind ports to dpdk::
+
+ ./usertools/dpdk-devbind.py --bind=vfio-pci 18:00.0 18.00.1 88:00.0 88:00.1
+
+2.Launch the dpdk testpmd with teltmetry::
+
+ ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd --telemetry -- -i
+
+3.Launch the telemetry client::
+
+ python ./usertools/dpdk-telemetry.py
+
+4.Excute command in telemtry client::
+
+ --> /ethdev/module_eeprom,<port number>
+
+5.check the testpmd and telemetry show info same as 'ethtool -m'::
+
+ ethtool -m ens25f1 | grep 'Laser output power'
+ Laser output power : 0.6703 mW / -1.74 dBm
+
+Test case: check Laser Power in different optical modules
+=========================================================
+
+1.set port 0 and port 1 with diffent optical modules
+
+2.Launch the dpdk testpmd with teltmetry::
+
+ ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd --telemetry -- -i
+
+3.Launch the telemetry client::
+
+ python ./usertools/dpdk-telemetry.py
+
+4.Excute command in telemtry client::
+
+ --> /ethdev/module_eeprom,0
+ --> /ethdev/module_eeprom,1
+
+5.check port 0 and port 1 have different Laser Power
+
+Test case: check Laser Power in same optical modules
+====================================================
+
+1.set port 0 and port 1 with same optical modules
+
+2.Launch the dpdk testpmd with teltmetry::
+
+ ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd --telemetry -- -i
+
+3.Launch the telemetry client::
+
+ python ./usertools/dpdk-telemetry.py
+
+4.Excute command in telemtry client::
+
+ --> /ethdev/module_eeprom,0
+ --> /ethdev/module_eeprom,1
+
+5.check port 0 and port 1 have same Laser Power
+
+.. note::
+
+ the laser power will change slightly with the voltage and temperature