[v3,11/14] net/mlx5: aso flow meter send WQE and CQE handle

Message ID 20210413001033.1999355-12-lizh@nvidia.com (mailing list archive)
State Superseded, archived
Delegated to: Raslan Darawsheh
Headers
Series Add ASO meter support in MLX5 PMD |

Checks

Context Check Description
ci/checkpatch success coding style OK

Commit Message

Li Zhang April 13, 2021, 12:10 a.m. UTC
ASO flow meter send WQE and CQE handle functions

Signed-off-by: Li Zhang <lizh@nvidia.com>
Acked-by: Matan Azrad <matan@nvidia.com>
---
 drivers/net/mlx5/mlx5.h            |   4 +
 drivers/net/mlx5/mlx5_flow_aso.c   | 183 ++++++++++++++++++++++++++++-
 drivers/net/mlx5/mlx5_flow_meter.c | 143 +++++++++++++---------
 3 files changed, 274 insertions(+), 56 deletions(-)
  

Patch

diff --git a/drivers/net/mlx5/mlx5.h b/drivers/net/mlx5/mlx5.h
index a604c403d1..30372e586b 100644
--- a/drivers/net/mlx5/mlx5.h
+++ b/drivers/net/mlx5/mlx5.h
@@ -1531,5 +1531,9 @@  int mlx5_aso_flow_hit_queue_poll_start(struct mlx5_dev_ctx_shared *sh);
 int mlx5_aso_flow_hit_queue_poll_stop(struct mlx5_dev_ctx_shared *sh);
 void mlx5_aso_queue_uninit(struct mlx5_dev_ctx_shared *sh,
 		enum mlx5_access_aso_opc_mod aso_opc_mod);
+int mlx5_aso_meter_update_by_wqe(struct mlx5_dev_ctx_shared *sh,
+		struct mlx5_aso_mtr *mtr);
+int mlx5_aso_mtr_wait(struct mlx5_dev_ctx_shared *sh,
+		struct mlx5_aso_mtr *mtr);
 
 #endif /* RTE_PMD_MLX5_H_ */
diff --git a/drivers/net/mlx5/mlx5_flow_aso.c b/drivers/net/mlx5/mlx5_flow_aso.c
index 067471ba0f..fe5c9912f2 100644
--- a/drivers/net/mlx5/mlx5_flow_aso.c
+++ b/drivers/net/mlx5/mlx5_flow_aso.c
@@ -13,7 +13,6 @@ 
 #include "mlx5.h"
 #include "mlx5_flow.h"
 
-
 /**
  * Destroy Completion Queue used for ASO access.
  *
@@ -657,3 +656,185 @@  mlx5_aso_flow_hit_queue_poll_stop(struct mlx5_dev_ctx_shared *sh)
 	}
 	return -rte_errno;
 }
+
+static uint16_t
+mlx5_aso_mtr_sq_enqueue_single(struct mlx5_aso_sq *sq,
+		struct mlx5_aso_mtr *aso_mtr)
+{
+	volatile struct mlx5_aso_wqe *wqe = NULL;
+	struct mlx5_flow_meter_info *fm = NULL;
+	uint16_t size = 1 << sq->log_desc_n;
+	uint16_t mask = size - 1;
+	uint16_t res = size - (uint16_t)(sq->head - sq->tail);
+	uint32_t dseg_idx = 0;
+	struct mlx5_aso_mtr_pool *pool = NULL;
+
+	if (unlikely(!res)) {
+		DRV_LOG(ERR, "Fail: SQ is full and no free WQE to send");
+		return 0;
+	}
+	wqe = &sq->sq_obj.aso_wqes[sq->head & mask];
+	rte_prefetch0(&sq->sq_obj.aso_wqes[(sq->head + 1) & mask]);
+	/* Fill next WQE. */
+	fm = &aso_mtr->fm;
+	sq->elts[sq->head & mask].mtr = aso_mtr;
+	pool = container_of(aso_mtr, struct mlx5_aso_mtr_pool,
+			mtrs[aso_mtr->offset]);
+	wqe->general_cseg.misc = rte_cpu_to_be_32(pool->devx_obj->id +
+			(aso_mtr->offset >> 1));
+	wqe->general_cseg.opcode = rte_cpu_to_be_32(MLX5_OPCODE_ACCESS_ASO |
+			(ASO_OPC_MOD_POLICER <<
+			WQE_CSEG_OPC_MOD_OFFSET) |
+			sq->pi << WQE_CSEG_WQE_INDEX_OFFSET);
+	/* There are 2 meters in one ASO cache line. */
+	dseg_idx = aso_mtr->offset & 0x1;
+	wqe->aso_cseg.data_mask =
+		RTE_BE64(MLX5_IFC_FLOW_METER_PARAM_MASK << (32 * !dseg_idx));
+	if (fm->is_enable) {
+		wqe->aso_dseg.mtrs[dseg_idx].cbs_cir =
+			fm->profile->srtcm_prm.cbs_cir;
+		wqe->aso_dseg.mtrs[dseg_idx].ebs_eir =
+			fm->profile->srtcm_prm.ebs_eir;
+	} else {
+		wqe->aso_dseg.mtrs[dseg_idx].cbs_cir =
+			RTE_BE32(MLX5_IFC_FLOW_METER_DISABLE_CBS_CIR_VAL);
+		wqe->aso_dseg.mtrs[dseg_idx].ebs_eir = 0;
+	}
+	sq->head++;
+	sq->pi += 2;/* Each WQE contains 2 WQEBB's. */
+	rte_io_wmb();
+	sq->sq_obj.db_rec[MLX5_SND_DBR] = rte_cpu_to_be_32(sq->pi);
+	rte_wmb();
+	*sq->uar_addr = *(volatile uint64_t *)wqe; /* Assume 64 bit ARCH. */
+	rte_wmb();
+	return 1;
+}
+
+static void
+mlx5_aso_mtrs_status_update(struct mlx5_aso_sq *sq, uint16_t aso_mtrs_nums)
+{
+	uint16_t size = 1 << sq->log_desc_n;
+	uint16_t mask = size - 1;
+	uint16_t i;
+	struct mlx5_aso_mtr *aso_mtr = NULL;
+	uint8_t exp_state = ASO_METER_WAIT;
+
+	for (i = 0; i < aso_mtrs_nums; ++i) {
+		aso_mtr = sq->elts[(sq->tail + i) & mask].mtr;
+		MLX5_ASSERT(aso_mtr);
+		(void)__atomic_compare_exchange_n(&aso_mtr->state,
+				&exp_state, ASO_METER_READY,
+				false, __ATOMIC_RELAXED, __ATOMIC_RELAXED);
+	}
+}
+
+static void
+mlx5_aso_mtr_completion_handle(struct mlx5_aso_sq *sq)
+{
+	struct mlx5_aso_cq *cq = &sq->cq;
+	volatile struct mlx5_cqe *restrict cqe;
+	const unsigned int cq_size = 1 << cq->log_desc_n;
+	const unsigned int mask = cq_size - 1;
+	uint32_t idx;
+	uint32_t next_idx = cq->cq_ci & mask;
+	const uint16_t max = (uint16_t)(sq->head - sq->tail);
+	uint16_t n = 0;
+	int ret;
+
+	if (unlikely(!max))
+		return;
+	do {
+		idx = next_idx;
+		next_idx = (cq->cq_ci + 1) & mask;
+		rte_prefetch0(&cq->cq_obj.cqes[next_idx]);
+		cqe = &cq->cq_obj.cqes[idx];
+		ret = check_cqe(cqe, cq_size, cq->cq_ci);
+		/*
+		 * Be sure owner read is done before any other cookie field or
+		 * opaque field.
+		 */
+		rte_io_rmb();
+		if (ret != MLX5_CQE_STATUS_SW_OWN) {
+			if (likely(ret == MLX5_CQE_STATUS_HW_OWN))
+				break;
+			mlx5_aso_cqe_err_handle(sq);
+		} else {
+			n++;
+		}
+		cq->cq_ci++;
+	} while (1);
+	if (likely(n)) {
+		mlx5_aso_mtrs_status_update(sq, n);
+		sq->tail += n;
+		rte_io_wmb();
+		cq->cq_obj.db_rec[0] = rte_cpu_to_be_32(cq->cq_ci);
+	}
+}
+
+/**
+ * Update meter parameter by send WQE.
+ *
+ * @param[in] dev
+ *   Pointer to Ethernet device.
+ * @param[in] priv
+ *   Pointer to mlx5 private data structure.
+ * @param[in] fm
+ *   Pointer to flow meter to be modified.
+ *
+ * @return
+ *   0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+int
+mlx5_aso_meter_update_by_wqe(struct mlx5_dev_ctx_shared *sh,
+			struct mlx5_aso_mtr *mtr)
+{
+	struct mlx5_aso_sq *sq = &sh->mtrmng->sq;
+	uint32_t poll_wqe_times = MLX5_MTR_POLL_WQE_CQE_TIMES;
+
+	do {
+		mlx5_aso_mtr_completion_handle(sq);
+		if (mlx5_aso_mtr_sq_enqueue_single(sq, mtr))
+			return 0;
+		/* Waiting for wqe resource. */
+		rte_delay_us_sleep(MLX5_ASO_WQE_CQE_RESPONSE_DELAY);
+	} while (--poll_wqe_times);
+	DRV_LOG(ERR, "Fail to send WQE for ASO meter %d",
+			mtr->fm.meter_id);
+	return -1;
+}
+
+/**
+ * Wait for meter to be ready.
+ *
+ * @param[in] dev
+ *   Pointer to Ethernet device.
+ * @param[in] priv
+ *   Pointer to mlx5 private data structure.
+ * @param[in] fm
+ *   Pointer to flow meter to be modified.
+ *
+ * @return
+ *   0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+int
+mlx5_aso_mtr_wait(struct mlx5_dev_ctx_shared *sh,
+			struct mlx5_aso_mtr *mtr)
+{
+	struct mlx5_aso_sq *sq = &sh->mtrmng->sq;
+	uint32_t poll_cqe_times = MLX5_MTR_POLL_WQE_CQE_TIMES;
+
+	if (__atomic_load_n(&mtr->state, __ATOMIC_RELAXED) ==
+					    ASO_METER_READY)
+		return 0;
+	do {
+		mlx5_aso_mtr_completion_handle(sq);
+		if (__atomic_load_n(&mtr->state, __ATOMIC_RELAXED) ==
+					    ASO_METER_READY)
+			return 0;
+		/* Waiting for CQE ready. */
+		rte_delay_us_sleep(MLX5_ASO_WQE_CQE_RESPONSE_DELAY);
+	} while (--poll_cqe_times);
+	DRV_LOG(ERR, "Fail to poll CQE ready for ASO meter %d",
+			mtr->fm.meter_id);
+	return -1;
+}
diff --git a/drivers/net/mlx5/mlx5_flow_meter.c b/drivers/net/mlx5/mlx5_flow_meter.c
index ef4ca30e4a..fcefc135b4 100644
--- a/drivers/net/mlx5/mlx5_flow_meter.c
+++ b/drivers/net/mlx5/mlx5_flow_meter.c
@@ -540,56 +540,79 @@  static int
 mlx5_flow_meter_action_modify(struct mlx5_priv *priv,
 		struct mlx5_flow_meter_info *fm,
 		const struct mlx5_flow_meter_srtcm_rfc2697_prm *srtcm,
-		uint64_t modify_bits, uint32_t active_state)
+		uint64_t modify_bits, uint32_t active_state, uint32_t is_enable)
 {
 #ifdef HAVE_MLX5_DR_CREATE_ACTION_FLOW_METER
 	uint32_t in[MLX5_ST_SZ_DW(flow_meter_parameters)] = { 0 };
 	uint32_t *attr;
 	struct mlx5dv_dr_flow_meter_attr mod_attr = { 0 };
 	int ret;
+	struct mlx5_aso_mtr *aso_mtr = NULL;
 	uint32_t cbs_cir, ebs_eir, val;
 
-	/* Fill command parameters. */
-	mod_attr.reg_c_index = priv->mtr_color_reg - REG_C_0;
-	mod_attr.flow_meter_parameter = in;
-	mod_attr.flow_meter_parameter_sz =
+	if (priv->sh->meter_aso_en) {
+		fm->is_enable = !!is_enable;
+		aso_mtr = container_of(fm, struct mlx5_aso_mtr, fm);
+		ret = mlx5_aso_meter_update_by_wqe(priv->sh, aso_mtr);
+		if (ret)
+			return ret;
+		ret = mlx5_aso_mtr_wait(priv->sh, aso_mtr);
+		if (ret)
+			return ret;
+	} else {
+		/* Fill command parameters. */
+		mod_attr.reg_c_index = priv->mtr_color_reg - REG_C_0;
+		mod_attr.flow_meter_parameter = in;
+		mod_attr.flow_meter_parameter_sz =
 				MLX5_ST_SZ_BYTES(flow_meter_parameters);
-	if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_ACTIVE)
-		mod_attr.active = !!active_state;
-	else
-		mod_attr.active = 0;
-	attr = in;
-	cbs_cir = rte_be_to_cpu_32(srtcm->cbs_cir);
-	ebs_eir = rte_be_to_cpu_32(srtcm->ebs_eir);
-	if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS) {
-		val = (cbs_cir >> ASO_DSEG_CBS_EXP_OFFSET) & ASO_DSEG_EXP_MASK;
-		MLX5_SET(flow_meter_parameters, attr, cbs_exponent, val);
-		val = (cbs_cir >> ASO_DSEG_CBS_MAN_OFFSET) & ASO_DSEG_MAN_MASK;
-		MLX5_SET(flow_meter_parameters, attr, cbs_mantissa, val);
-	}
-	if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR) {
-		val = (cbs_cir >> ASO_DSEG_CIR_EXP_OFFSET) & ASO_DSEG_EXP_MASK;
-		MLX5_SET(flow_meter_parameters, attr, cir_exponent, val);
-		val = cbs_cir & ASO_DSEG_MAN_MASK;
-		MLX5_SET(flow_meter_parameters, attr, cir_mantissa, val);
-	}
-	if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_EBS) {
-		val = (ebs_eir >> ASO_DSEG_EBS_EXP_OFFSET) & ASO_DSEG_EXP_MASK;
-		MLX5_SET(flow_meter_parameters, attr, ebs_exponent, val);
-		val = (ebs_eir >> ASO_DSEG_EBS_MAN_OFFSET) & ASO_DSEG_MAN_MASK;
-		MLX5_SET(flow_meter_parameters, attr, ebs_mantissa, val);
-	}
-	/* Apply modifications to meter only if it was created. */
-	if (fm->mfts->meter_action) {
-		ret = mlx5_glue->dv_modify_flow_action_meter
+		if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_ACTIVE)
+			mod_attr.active = !!active_state;
+		else
+			mod_attr.active = 0;
+		attr = in;
+		cbs_cir = rte_be_to_cpu_32(srtcm->cbs_cir);
+		ebs_eir = rte_be_to_cpu_32(srtcm->ebs_eir);
+		if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS) {
+			val = (cbs_cir >> ASO_DSEG_CBS_EXP_OFFSET) &
+				ASO_DSEG_EXP_MASK;
+			MLX5_SET(flow_meter_parameters, attr,
+				cbs_exponent, val);
+			val = (cbs_cir >> ASO_DSEG_CBS_MAN_OFFSET) &
+				ASO_DSEG_MAN_MASK;
+			MLX5_SET(flow_meter_parameters, attr,
+				cbs_mantissa, val);
+		}
+		if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR) {
+			val = (cbs_cir >> ASO_DSEG_CIR_EXP_OFFSET) &
+				ASO_DSEG_EXP_MASK;
+			MLX5_SET(flow_meter_parameters, attr,
+				cir_exponent, val);
+			val = cbs_cir & ASO_DSEG_MAN_MASK;
+			MLX5_SET(flow_meter_parameters, attr,
+				cir_mantissa, val);
+		}
+		if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_EBS) {
+			val = (ebs_eir >> ASO_DSEG_EBS_EXP_OFFSET) &
+				ASO_DSEG_EXP_MASK;
+			MLX5_SET(flow_meter_parameters, attr,
+				ebs_exponent, val);
+			val = (ebs_eir >> ASO_DSEG_EBS_MAN_OFFSET) &
+				ASO_DSEG_MAN_MASK;
+			MLX5_SET(flow_meter_parameters, attr,
+				ebs_mantissa, val);
+		}
+		/* Apply modifications to meter only if it was created. */
+		if (fm->mfts->meter_action) {
+			ret = mlx5_glue->dv_modify_flow_action_meter
 					(fm->mfts->meter_action, &mod_attr,
 					rte_cpu_to_be_64(modify_bits));
-		if (ret)
-			return ret;
+			if (ret)
+				return ret;
+		}
+		/* Update succeedded modify meter parameters. */
+		if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_ACTIVE)
+			fm->active_state = !!active_state;
 	}
-	/* Update succeedded modify meter parameters. */
-	if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_ACTIVE)
-		fm->active_state = !!active_state;
 	return 0;
 #else
 	(void)priv;
@@ -653,6 +676,7 @@  mlx5_flow_meter_create(struct rte_eth_dev *dev, uint32_t meter_id,
 		.type = "mlx5_flow_mtr_flow_id_pool",
 	};
 	struct mlx5_aso_mtr *aso_mtr;
+	union mlx5_l3t_data data;
 	uint32_t mtr_idx;
 	int ret;
 	uint8_t mtr_id_bits;
@@ -704,7 +728,6 @@  mlx5_flow_meter_create(struct rte_eth_dev *dev, uint32_t meter_id,
 	fm->profile = fmp;
 	memcpy(fm->action, params->action, sizeof(params->action));
 	mlx5_flow_meter_stats_enable_update(fm, params->stats_mask);
-
 	/* Alloc policer counters. */
 	if (fm->green_bytes || fm->green_pkts) {
 		fm->policer_stats.pass_cnt = mlx5_counter_alloc(dev);
@@ -727,12 +750,23 @@  mlx5_flow_meter_create(struct rte_eth_dev *dev, uint32_t meter_id,
 	if (!priv->sh->meter_aso_en)
 		TAILQ_INSERT_TAIL(fms, legacy_fm, next);
 	fm->active_state = 1; /* Config meter starts as active. */
+	fm->is_enable = 1;
 	fm->shared = !!shared;
 	__atomic_add_fetch(&fm->profile->ref_cnt, 1, __ATOMIC_RELAXED);
 	fm->flow_ipool = mlx5_ipool_create(&flow_ipool_cfg);
 	if (!fm->flow_ipool)
 		goto error;
 	rte_spinlock_init(&fm->sl);
+	/* If ASO meter supported, allocate ASO flow meter. */
+	if (priv->sh->meter_aso_en) {
+		aso_mtr = container_of(fm, struct mlx5_aso_mtr, fm);
+		ret = mlx5_aso_meter_update_by_wqe(priv->sh, aso_mtr);
+		if (ret)
+			goto error;
+		data.dword = mtr_idx;
+		if (mlx5_l3t_set_entry(priv->mtr_idx_tbl, meter_id, &data))
+			goto error;
+	}
 	return 0;
 error:
 	mlx5_flow_destroy_policer_rules(dev, fm, &attr);
@@ -878,12 +912,12 @@  mlx5_flow_meter_modify_state(struct mlx5_priv *priv,
 	int ret;
 
 	if (new_state == MLX5_FLOW_METER_DISABLE)
-		ret = mlx5_flow_meter_action_modify(priv, fm, &srtcm,
-						    modify_bits, 0);
+		ret = mlx5_flow_meter_action_modify(priv, fm,
+				&srtcm, modify_bits, 0, 0);
 	else
 		ret = mlx5_flow_meter_action_modify(priv, fm,
 						   &fm->profile->srtcm_prm,
-						    modify_bits, 0);
+						    modify_bits, 0, 1);
 	if (ret)
 		return -rte_mtr_error_set(error, -ret,
 					  RTE_MTR_ERROR_TYPE_MTR_PARAMS,
@@ -1031,7 +1065,7 @@  mlx5_flow_meter_profile_update(struct rte_eth_dev *dev,
 	if (fm->active_state == MLX5_FLOW_METER_DISABLE)
 		return 0;
 	ret = mlx5_flow_meter_action_modify(priv, fm, &fm->profile->srtcm_prm,
-					      modify_bits, fm->active_state);
+					      modify_bits, fm->active_state, 1);
 	if (ret) {
 		fm->profile = old_fmp;
 		return -rte_mtr_error_set(error, -ret,
@@ -1281,6 +1315,8 @@  mlx5_flow_meter_ops_get(struct rte_eth_dev *dev __rte_unused, void *arg)
  *   Pointer to mlx5_priv.
  * @param meter_id
  *   Meter id.
+ * @param mtr_idx
+ *   Pointer to Meter index.
  *
  * @return
  *   Pointer to the profile found on success, NULL otherwise.
@@ -1297,10 +1333,6 @@  mlx5_flow_meter_find(struct mlx5_priv *priv, uint32_t meter_id,
 
 	if (priv->sh->meter_aso_en) {
 		rte_spinlock_lock(&mtrmng->mtrsl);
-		if (!mtrmng->n_valid) {
-			rte_spinlock_unlock(&mtrmng->mtrsl);
-			return NULL;
-		}
 		if (mlx5_l3t_get_entry(priv->mtr_idx_tbl, meter_id, &data) ||
 			!data.dword) {
 			rte_spinlock_unlock(&mtrmng->mtrsl);
@@ -1309,17 +1341,18 @@  mlx5_flow_meter_find(struct mlx5_priv *priv, uint32_t meter_id,
 		if (mtr_idx)
 			*mtr_idx = data.dword;
 		aso_mtr = mlx5_aso_meter_by_idx(priv, data.dword);
+		/* Remove reference taken by the mlx5_l3t_get_entry. */
 		mlx5_l3t_clear_entry(priv->mtr_idx_tbl, meter_id);
-		if (meter_id == aso_mtr->fm.meter_id) {
-			rte_spinlock_unlock(&mtrmng->mtrsl);
-			return &aso_mtr->fm;
-		}
+		MLX5_ASSERT(meter_id == aso_mtr->fm.meter_id);
 		rte_spinlock_unlock(&mtrmng->mtrsl);
-	} else {
-		TAILQ_FOREACH(legacy_fm, fms, next)
-			if (meter_id == legacy_fm->fm.meter_id)
-				return &legacy_fm->fm;
+		return &aso_mtr->fm;
 	}
+	TAILQ_FOREACH(legacy_fm, fms, next)
+		if (meter_id == legacy_fm->fm.meter_id) {
+			if (mtr_idx)
+				*mtr_idx = legacy_fm->idx;
+			return &legacy_fm->fm;
+		}
 	return NULL;
 }