[v8,2/6] app/testpmd: dump device capability and Rx domain info

Message ID 20211018125942.2067353-3-xuemingl@nvidia.com (mailing list archive)
State Superseded, archived
Delegated to: Ferruh Yigit
Headers
Series [v8,1/6] ethdev: introduce shared Rx queue |

Checks

Context Check Description
ci/checkpatch success coding style OK

Commit Message

Xueming Li Oct. 18, 2021, 12:59 p.m. UTC
  Dump device capability and Rx domain ID if shared Rx queue is supported
by device.

Signed-off-by: Xueming Li <xuemingl@nvidia.com>
---
 app/test-pmd/config.c | 4 ++++
 1 file changed, 4 insertions(+)
  

Patch

diff --git a/app/test-pmd/config.c b/app/test-pmd/config.c
index 9c66329e96e..c0616dcd2fd 100644
--- a/app/test-pmd/config.c
+++ b/app/test-pmd/config.c
@@ -733,6 +733,7 @@  port_infos_display(portid_t port_id)
 	printf("Max segment number per MTU/TSO: %hu\n",
 		dev_info.tx_desc_lim.nb_mtu_seg_max);
 
+	printf("Device capabilities: 0x%"PRIx64"\n", dev_info.dev_capa);
 	/* Show switch info only if valid switch domain and port id is set */
 	if (dev_info.switch_info.domain_id !=
 		RTE_ETH_DEV_SWITCH_DOMAIN_ID_INVALID) {
@@ -743,6 +744,9 @@  port_infos_display(portid_t port_id)
 			dev_info.switch_info.domain_id);
 		printf("Switch Port Id: %u\n",
 			dev_info.switch_info.port_id);
+		if ((dev_info.dev_capa & RTE_ETH_DEV_CAPA_RXQ_SHARE) != 0)
+			printf("Switch Rx domain: %u\n",
+			       dev_info.switch_info.rx_domain);
 	}
 }